These cables are used as earthing cables and for installations requiring high conductivity and good flexibility for easy laying.
Construction :
Conductor: Bare Annealed Copper
Insulation: Bare Annealed Copper
Electrical Cable
Special cables
Paired Cables with Overall Screen
Ces câbles sont destinés pour les liaisons entre ordinateurs et équipements périphériques.
Constitution :
Ame : Cuivre étamé massif
Isolation : PVC
Ecran : Tresse en cuivre étamé
Assemblage : Ruban polyester
Gaine : PVC gris clair
Industrial LV Cables
Electrical Cable U 1000 SVOV
These cables are intended for industrial installations subject to heavy vibration.
Construction :
Conductor : Stranded copper
Insulation : PVC
Filler : PVC
Sheath : PVC Black
Ces câbles sont destinés aux équipements de machines outils et pour toutes liaisons souples ou une protection contre la présence d’huile ou d’acide est recherchée.
Constitution
Ame : Cuivre souple
Isolation : PVC souple
Bourrage : PVC souple
Gaine : PVC souple,Gris,résistant aux huiles minéraux
Caractéristiques
Tension nominale : 300/500 V...
Telecom Cables
Cable TELECOM CABLES 5/9
These cables are intended for individual subscriber service connections, particularly in built-up areas, taken from overhead network lines.
Construction
Conductor : Solid annealed copper
Insulation : PEHD Black
Characteristics
Conductor : Bare Annealed Copper massif Æ = 0,74 ± 0,02 mm
Special cables
Airfield Lighting Cables
Ces câbles sont destinés pour le balisage des pistes d’aérodrome.
Constitution :
Ame : Cuivre Nu ou étamé câblé
Isolation : PR ou PVC
Ecran : Ruban semi-conducteur + Ruban cuivre
Gaine : PE ou PVC
Autres : Semi-conducteur extrudé
These cables are intended to supply mobile or semi-fixed domestic appliances. Do not use them for heat-producing appliances.
Construction :
Conductor: flexible copperInsulation: PVCFiller: PVCSheath: PVC
Characteristics :
Rated voltage : 300/300 V
Conductor: class 5 flexible copper
Maximum permissible temperature : 70° C continuous / 150° C short...
Industrial LV Cables
Electrical Cable U 1000 SVOV
Ces câbles sont destinés à la télécommande et à l’instrumentation pour les installations soumises à des fortes vibrations.
Constitution :
Ame : Cuivre cablé
Isolation : PVC
Bourrage : PVC
Gaine : PVC Noir
Caractéristiques :
Tension nominale : 1000 V
Conducteur : Cuivre souple classe 5
Température max. admissible : 70° C En permanence / 150° C En...
Industrial LV Cables
Electrical Cable U 1000 SVOV Remote Control
These cables are intended for remote control and instrumentation in installations subject to heavy vibration.
Construction :
Conductor : Stranded copper
Insulation : PVC
Filler : PVC
Sheath : PVC
Industrial LV Cables
Electrical Cable NYY & NAYY
These cables are intended for industrial installations.
Construction :
Conductor : Solid or stranded copper/ Stranded aluminium (NAYY)
Insulation : PVC
Filler : PVC
Sheath : PVC Grey
Domestic LV Cables
Electrical Cable HO5 V-U & HO5 V2-U
This cable is intended for internal wiring and switchboard cabling.
Construction :
Conductor: solid copper
Insulation: coloured PVC
Characteristics :
Rated voltage : 300/500 V
Conductor: class 1 solid copper
Maximum permissible temperature :
70° C continuous (HO5 V-U)
90° C continuous (HO5 V2-U)
160° C short circuit
Conductor identification : Rouge...
Industrial LV Cables
Electrical Cable NYBY & NAYBY
These cables are intended for industrial installations requiring mechanical protection.
Construction :
Conductor : Solid or stranded copper Stranded aluminium (NAYBY)
Insulation : PVC
Filler : PVC
Armure : 2 Feuillards en acier
Sheath : PVC
These cables are intended to supply mobile or semi-fixed domestic appliances. Do not use them for heat-producing appliances.
Construction :
Conductor: flexible copper
Insulation: PVC
Filler: PVC
Sheath: PVC
Characteristics :
Rated voltage : 300/500 V
Conductor: class 5 flexible copper
Maximum permissible temperature : 70° C continuous / 150° C...
Industrial LV Cables
Electrical Cable NYY Remote Control
These cables are intended for remote control and instrumentation where required no anti-inductive screen (for example where there is no capacitive interaction).
NYY-R, with its stranded conductor, is intended more particularly for installations subject to vibration.
Construction:
Conductor: solid copper / stranded copper
Insulation : PVC
Filler : PVC...
Domestic LV Cables
Electrical Cable U500 SVOV
These cables are intended for machine-tool equipment and all flexible connections.
Construction :Conductor : Stranded copperInsulation : flexible PVCFiller : flexible PVCSheath : flexible PVC
Characteristics :
Rated voltage : 300/500 V & 450/750V
Conductor: class 5 flexible copper
Maximum permissible temperature : 70° C continuous 150° C short...
Industrial LV Cables
Electrical Cable NYBY Remote Control
These cables are intended for Remote Control whenever mechanical protection is required.
Construction
Conductor : Solid copper
solution : PVC
Filler : PVC (or ruban d’assemblage)
Armure : Deux feuillards acier
Sheath : PVC Grey
Domestic LV Cables
Electrical Cable S V M
These cables are intended to supply mobile or semi-fixed domestic appliances. Do not use them for heat-producing appliances.
Construction :
Conductor: flexible copper
Insulation: PVC
Characteristics :
Rated voltage : 300/300 V
Conductor: Cuivre souple classe 6
Maximum permissible temperature : 70° C continuous / 150° C short circuit
Industrial LV Cables
Electrical Cable NYY & NAYY
Ces câbles sont destinés aux installations industrielles.
Constitution :
Ame : Cuivre massif ou câblé/ Aluminium câblé (NAYY)
Isolation : PVC
Bourrage : PVC
Gaine : PVC gris
Caractéristiques :
Tension nominale : 0,6/1 Kv
Conducteur :
Cuivre massif (S b 6mm2) classe 1
Cuivre câblé (S a 6mm2) classe 2
Aluminium câblé classe 2{NAYY}
Température max....
Electrical Cable
Cable NYBY
These cables are intended for industrial installations requiring mechanical protection.
Electrical Cable
Cable U 1000 AR2V
These cables are intended for installation
s industrielles, building rising mains Street Lighting BT. This cable should not be used in ground that is flooded for more than two months a year.
Electrical Cable
Cable U 1000 R2V
These cables are intended for industrial installations, building rising mains Street Lighting BT. This cable should not be used in ground that is flooded for more than two months a year.
Electrical Cable
Bare or Greased Copper/Aluminium Cable
These cables are used for overhead lines in power distribution and transmission networks requiring high mechanical tension.
Construction
Conductor: Aluminium câblé (n couches)
Insulation: CONDUCTEUR ALUMINIUM / ACCIER NU GRAISSÉ
Electrical Cable
Cable U 1000 ARVFV
These cables are intended for industrial installations requiring mechanical protection.
Electrical Cable
Cable U1000 RVFV